Equipment
INTACHEM’s licensed Textile Media Filter (TMF) is at the leading edge of solids / liquid separation. It is primarily a clarifier that can be adapted to a broad range of applications.
The Textile Media Filter (TMF) is comparable to a high performance sand filter. However the Textile Media Filter (TMF) has a footprint approximately eleven times smaller, has a higher flux and a greater capture. It is robust with minimal moving parts and simply adaptable process control. It is compatible with filter aids effectively giving the Textile Media Filter (TMF) ion selective capabilities.
Equipment includes
-
Potable Water Treatment
-
Waste Water Treatment
-
Oil and Gas
-
Clarification of various liquors in Minerals Processing applications.
Case Studies
Request
Design filter plant, Fabricate, Supervise Install, Commission, Train operators, with project management by Ausenco Engineers
Raw water TSS up to 500mg/L, main contaminants are clay silt particles and process precipitated iron
Filtrate less than 0.5mg/L at nominal capacity 140m3/hr/plant with 2 filter tanks
Service – 24/7/365, Online Availability >95%
Pressure Vessel Design Code - AS1210 + 4mm corrosion allowance
Status communication by electrical signalsto plant control computer
All documentation and training in dual language
Manufactured in China with independent customer inspection
Performance Guaranteed design
Extended Product Warranty
Description
Raw Water and Filtrate tank levels are PLC monitored to maintain safe operation and operation on demand.
The PLC can on off signal a chemical pre-treatment plant when required.
The filters are fully automated with multiple criteria based control including filtrate turbidity analysis capability
Commission Date
April 2012Project Status
Manufacturer’s design has more than fulfilled all design expectations and performance expectations.As of Jan 2013, no replacement consumable parts have been purchased by the customer.
Request
Design, Fabricate, Supervise Install, Commission, Train operators with project introduction by Kappes Cassidy Associates.
Alkaline Sodium Cyanide PLS from Dump Leach, main contaminants are clay silt particles
Turbidity of PLS feed can exceed 500mg/L TSS
Filtrate less than 5mg/L
Capacity 200m3/hr/plant
Service – 24/7/365 with Online Availability >97.5%
Fully PLC automated handsfree filters, with optional manual override.
Electrical Status communication to plant control computer
All documentation and training in dual language
Mild Steel – Epoxy internal coating
Pressure Design Code ASME (BVPC) + 150% overdesign factor.
Description
PLS flows from the dump pad to a short residence storage tank, then to the filter feed pump.
Backwash conducted in the raw water.
1 x FM-UB-2625 model Fabric Media Water Filters – fully automated with backpressure or time criteria based control.
Filtrate reports directly to a Ion Exchange column.
Commission Date
August 2005Project Status
Manufactures design and process knowhow has more than fulfilled all design expectations and performance expectations.Request
Design, Fabricate, Supervise Installation, Commission, Train operators, with project management by REG Mineral Processing Services.
Alkaline Sodium Cyanide PLS from heap Leach pads collection pond, maincontaminants calcium silicate precipitates
Filtrate less than 5mg/L
Capacity 200m3/hr/plant
Service – 24/7/365 with Online Availability >97.5%
Fully PLC automated handsfree filters, with optional manual override.
Modbus communication to plant control computer
Mild Steel – Epoxy internal coating
Pressure Design Code AS1210
Description
PLS flows from the collection pond through the filter to the de-aeration tower of the Merrill-Crowe circuit.
Backwash conducted in the PLS.
1 x FM-UA-2125 model Fabric Media Water Filters – fully automated with backpressure or time criteria based control.
Commission Date
August 2011Project Status
Manufactures design and process knowhow has more than fulfilled all design expectations and performance expectations.Request
Design, Fabricate, Supervise Installation, Commission, Train operators, with project management by REG Mineral Processing Services.
Alkaline Sodium Cyanide PLS from heap Leach pads collection pond, maincontaminants calcium silicate precipitates
Filtrate less than 5mg/L
Capacity 200m3/hr/plant
Service – 24/7/365 with Online Availability >97.5%
Fully PLC automated handsfree filters, with optional manual override.
Modbus communication to plant control computer
Mild Steel – Epoxy internal coating
Pressure Design Code AS1210
Description
PLS flows from the collection pond through the filter to the de-aeration tower of the Merrill-Crowe circuit.
Backwash conducted in the PLS.
1 x FM-UA-2125 model Fabric Media Water Filters – fully automated with backpressure or time criteria based control.
Commission Date
August 2011Project Status
Manufactures design and process knowhow has more than fulfilled all design expectations and performance expectations.Contact Us
INTACHEM also supply Minerals Processing reagents such as Depressants, Activators, Collectors, Promoters and Frothers.